GetHumRatioFromRelHum: Return humidity ratio given dry-bulb temperature, relative...

Description Usage Arguments Value References Examples

Description

Return humidity ratio given dry-bulb temperature, relative humidity, and pressure.

Usage

1
GetHumRatioFromRelHum(TDryBulb, RelHum, Pressure)

Arguments

TDryBulb

A numeric vector of dry-bulb temperature in degreeF [IP] or degreeC [SI]

RelHum

A numeric vector of relative humidity in range [0, 1]

Pressure

A numeric vector of atmospheric Pressure in Psi [IP] or Pa [SI]

Value

A numeric vector of humidity ratio in lb_H2O lb_Air-1 [IP] or kg_H2O kg_Air-1 [SI]

References

ASHRAE Handbook - Fundamentals (2017) ch. 1

Examples

1
2
3
4
5
SetUnitSystem("IP")
GetHumRatioFromRelHum(80:100, 0.5, 14.175)

SetUnitSystem("SI")
GetHumRatioFromRelHum(20:30, 0.5, 95461.0)

psychrolib documentation built on May 29, 2021, 9:11 a.m.