functions.grid: Electrical Power Grid

Description Usage Arguments Details Value Note Author(s) References Examples

Description

Electric power systems calculations including buses and loads

Usage

1
2
3
4
5
infinite.bus(x)
seg.ts(Xts,dh0,dhf,var) 
series.plot(x.t)
daily.min.max(x.t.y, ylabel, inst.cap, inst.lab)
load.duration(x.t.y, inst.cap, inst.lab)

Arguments

x

parameters for infinite bus a list(V,X,E,delta):V Voltage, X Reactance, E array of electromotive force, delta array of angle delta

Xts

data frame with ts values

dh0

intial time stamp

dhf

final time stamp

var

variable number to select

x.t

time series to plot

x.t.y

load time series for daily.min.max plots and load-duration curve

ylabel

label for min max

inst.cap

array of installed capacities

inst.lab

array of labels for installed capacities

Details

infinite.bus uses a fixed V and X, and plots the effect of a set of E and angle delta daily.min.max draws a plot showing daily maximum and minimum along with horizontal lines for installed capacities load.duration builds a load-duration curve and calculate CF for daily load data and a set of generation capacities

Value

Hours

number of hours for each class

energy

total energy under curve

possible

possible utilization for each class

utilization

actual utilization for each class

CF

capacity factor for each class

Note

Functions used in Chapter 11 of Acevedo (2018)

Author(s)

Miguel F. Acevedo acevedo@unt.edu

References

Acevedo, M.F. 2018. Introduction to Renewable Electric Power Systems and the Environment with R. Boca Raton, FL: CRC Press. (ISBN 9781138197343)

Examples

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
x <- list(V=13.8,X=1,E=seq(14,16,1),delta=seq(6,30,1))
infinite.bus(x)

X <- ERCOT2010
x.t <- seg.ts(X,dh0="1/1/2010 1:00",dhf="1/1/2011 0:00",c(1:9))$x.t

# week day Monday Jan 04 2010
x.t.wd.wt <- seg.ts(X,dh0="1/4/2010 0:00",dhf="1/4/2010 23:00",c(1,5,7))$x.t.seg
series.plot(x.t.wd.wt) 

# week Sunday Jan 24 to Saturday Jan 30 2010
x.t.wd.wt <- seg.ts(X,dh0="1/24/2010 0:00",dhf="1/30/2010 23:00",c(1,5,7))$x.t.seg
series.plot(x.t.wd.wt)

# NORTH_C
x.t.y <- x.t[,5]; ylabel <- colnames(x.t)[5]; inst.cap <- c(10000,8000,8000) #MW
inst.lab <- c("Baseload","Intermediate", "Peaking")
daily.min.max(x.t.y,ylabel,inst.cap,inst.lab)

x.t.y <- x.t[,5]
inst.cap <- c(10000,8000,8000) # MW
inst.lab <- c("Baseload","Intermediate", "Peaking")
load.duration(x.t.y, inst.cap,inst.lab)