pk_1cmt_inf_cmax_ss: Cmax for linear 1-compartment PK model at steady state

pk_1cmt_inf_cmax_ssR Documentation

Cmax for linear 1-compartment PK model at steady state

Description

Takes single values for dose or model parameters, or vector of either dose or parameters (but not both).

Usage

pk_1cmt_inf_cmax_ss(dose, tau, CL, V, t_inf, ruv = NULL)

Arguments

dose

dose

tau

dosing interval

CL

clearance

V

volume of distrubition

t_inf

infusion time

ruv

residual variability, specified as list with optional arguments for proportional, additive, or exponential components, e.g. list(prop=0.1, add=1, exp=0)

Examples

pk_1cmt_inf_cmax_ss(dose = 500, tau = 12, t_inf = 2, CL = 5, V = 50)