pk_2cmt_inf: Concentration predictions for 1-compartmental PK model,...

Description Usage Arguments

Description

Concentration predictions for 1-compartmental PK model, single or multiple infusions

Usage

1
2
pk_2cmt_inf(t = c(0:24), dose = 100, tau = 12, t_inf = 1, CL = 3,
  V = 30, Q = 2, V2 = 20, ruv = NULL)

Arguments

t

vector of time

dose

dose

tau

dosing interval

t_inf

infusion time

CL

clearance

V

volume of central compartment

Q

inter-compartimental clearance

V2

volume of peripheral compartment

ruv

residual error (list)