Nothing
# read isodat .did file
# @param ds the data structure to fill
# @param custom reader options - none needed
iso_read_did <- function(ds, options = list()) {
# safety checks
if(!iso_is_dual_inlet(ds))
stop("data structure must be a 'dual_inlet' iso_file", call. = FALSE)
# read binary file
ds$binary <- get_ds_file_path(ds) %>% read_binary_file()
# process file info
if(ds$read_options$file_info) {
ds <- exec_func_with_error_catch(extract_isodat_sequence_line_info, ds)
ds <- exec_func_with_error_catch(extract_isodat_measurement_info, ds)
ds <- exec_func_with_error_catch(extract_isodat_datetime, ds)
ds <- exec_func_with_error_catch(extract_MS_integration_time_info, ds)
}
# process raw data
if (ds$read_option$raw_data)
ds <- exec_func_with_error_catch(extract_did_raw_voltage_data, ds)
# process method info
if (ds$read_options$method_info) {
ds <- exec_func_with_error_catch(extract_isodat_reference_values, ds) # NOTE: no cap for these
ds <- exec_func_with_error_catch(extract_isodat_resistors, ds)
}
# process pre-evaluated data table
if (ds$read_options$vendor_data_table)
ds <- exec_func_with_error_catch(extract_did_vendor_data_table, ds)
return(ds)
}
# extract voltage data in did file
extract_did_raw_voltage_data <- function(ds) {
# mass information
ds$binary <- ds$binary %>%
set_binary_file_error_prefix("cannot identify measured masses") %>%
move_to_C_block("CBinary") %>%
move_to_next_C_block_range("CTraceInfoEntry", "CPlotRange")
# read all masses
masses_re <- re_combine(re_block("fef-x"), re_text("Mass "))
masses_positions <- find_next_patterns(ds$binary, masses_re)
masses <- map_chr(masses_positions, function(pos) {
ds$binary %>%
move_to_pos(pos + masses_re$size) %>%
capture_data("mass", "text", re_or(re_block("fef-x"), re_block("C-block")),
data_bytes_max = 8, move_past_dots = FALSE) %>%
{ .$data$mass }
})
# mass column formatting
masses_columns <- str_c("v", masses, ".mV")
# locate voltage data
ds$binary <- ds$binary %>%
set_binary_file_error_prefix("cannot locate voltage data") %>%
move_to_C_block_range("CDualInletRawData", "CTwoDoublesArrayData") %>%
move_to_next_C_block("CIntegrationUnitTransferPart") %>%
set_binary_file_error_prefix("cannot process voltage data")
# find binary positions for voltage standards and samples
voltages <- list()
standard_voltage_start_re <- re_combine(re_text("/"), re_block("fef-x"), re_block("fef-x"), re_text("Standard "))
standard_positions <- find_next_patterns(ds$binary, standard_voltage_start_re)
sample_voltage_start_re <- re_combine(re_text("/"), re_block("fef-0"), re_block("fef-x"), re_text("Sample "))
sample_positions <- find_next_patterns(ds$binary, sample_voltage_start_re)
# function to capture voltages
capture_voltages <- function(pos) {
bin <- ds$binary %>%
move_to_pos(pos) %>%
capture_data("cycle", "text", re_null(4), re_block("stx"), move_past_dots = TRUE) %>%
move_to_next_pattern(re_text("/"), re_block("fef-0"), re_block("fef-0"), re_null(4), re_block("stx")) %>%
move_to_next_pattern(re_block("x-000"), re_block("x-000")) %>%
capture_data("voltage", "double", re_null(6),re_block("x-000"), sensible = c(-1000, 100000))
# safety check
if (length(bin$data$voltage) != length(masses)) {
op_error(bin, glue("inconsistent number of voltage measurements encountered ({length(bin$data$voltage)}), expected {length(masses)}"))
}
# return voltage data
return(tibble(cycle = bin$data$cycle, cup = 1:length(bin$data$voltage), voltage = bin$data$voltage))
}
# assemble voltages data frame
voltages <-
bind_rows(
tibble(pos = standard_positions + standard_voltage_start_re$size, type = "standard"),
tibble(pos = sample_positions + sample_voltage_start_re$size, type = "sample")
) %>%
mutate(
voltages = map(.data$pos, capture_voltages)
) %>%
unnest(voltages) %>%
# join in the mass information
left_join(tibble(cup = 1:length(masses), mass = masses_columns), by = "cup") %>%
# spread out the volrages
select(-.data$pos, -.data$cup) %>%
spread(.data$mass, .data$voltage) %>%
# update cycle
mutate(cycle = as.integer(ifelse(.data$cycle == "Pre", -1L, .data$cycle)) + 1L)
# voltages data frame
ds$raw_data <- arrange(voltages, desc(.data$type), .data$cycle)
return(ds)
}
# extract vendor computed data table
# @note this could potentially also use the more universal data table functions in iso_read_isodat
extract_did_vendor_data_table <- function(ds) {
# find vendor data table
ds$binary <- ds$binary %>%
set_binary_file_error_prefix("cannot process vendor computed data table") %>%
move_to_C_block_range("CDualInletEvaluatedData", "CParsedEvaluationString")
# cap
if (!is.null(pos <- find_next_pattern(ds$binary, re_text("Gas Indices")))) {
ds$binary <- ds$binary %>% cap_at_pos(pos - 20)
} else op_error(ds$binary, "cannot find data deliminter 'Gas Indices'")
# find data positions
column_header_re <- re_combine(re_block("etx"), re_text("/"), re_block("fef-x"), re_block("text"), # Delta or AT%
re_block("fef-x"), re_block("text"), # actual column name
re_null(4), re_block("stx"))
column_data_re <- re_combine(re_text("/"), re_block("fef-0"), re_block("fef-x"), re_block("text"), re_null(4),
re_block("x-000"), re_block("x-000")) # data comes after this
column_header_positions <- find_next_patterns(ds$binary, column_header_re)
column_data_positions <- find_next_patterns(ds$binary, column_data_re)
# safety checks
if (length(column_header_positions) == 0) {
op_error(ds$binary, "no column headers found")
} else if (length(column_header_positions) != length(column_data_positions)) {
op_error(ds$binary, sprintf("unequal number of column headers (%d) and data entries (%d) found",
length(column_header_positions), length(column_data_positions)))
} else if (!all(column_header_positions < column_data_positions)) {
op_error(ds$binary, "found column headers not interspersed with data entries")
}
# read the data
vendor_dt <- list()
for (i in 1:length(column_header_positions)) {
ds$binary <- ds$binary %>%
move_to_pos(column_header_positions[i] + 10) %>% # skip initial <stx>/<fef-x> at the start of header
# capture column type (typically Delta or AT%) # could skip this to speed up
capture_data("type", "text", re_block("fef-x"), move_past_dots = TRUE) %>%
# capture actual colum name
capture_data("column", "text", re_null(4), re_block("stx")) %>%
# capture column data
move_to_pos(column_data_positions[i]) %>%
move_to_next_pattern(column_data_re, max_gap = 0) %>% # move to start of data
capture_n_data("n_values", "integer", n = 1, sensible = c(1, 1000)) %>% # NOTE: this assumes more than 1000 cycles are unrealistic in dual inlet
capture_data("values", "double", re_block("fef-0"), re_block("stx"), sensible = c(-1e10, 1e10))
# safety check
if (length(ds$binary$data$values) != 2 * ds$binary$data$n_values)
glue::glue("inconsistent number of data entries recovered ({length(ds$binary$data$values)}) - ",
"expected {2 * ds$binary$data$n_values} values from {ds$binary$data$n_values} cycles") %>%
stop(call. = FALSE)
table_column <- list(
list(
cycle = as.integer(ds$binary$data$values[c(TRUE, FALSE)] + 1L),
value = ds$binary$data$values[c(FALSE, TRUE)]
)) %>% rlang::set_names(str_replace(ds$binary$data$column, "\\s*$", "")) # remove trailing white spaces in column names
vendor_dt <- c(vendor_dt, table_column)
}
# safety checks
if (length(vendor_dt) == 0) stop("no vendor computed data found", call. = FALSE)
cycles <- lapply(vendor_dt, `[[`, 1)
if (!all(sapply(cycles, identical, cycles[[1]])))
stop("not all columns have the same number of cycles", call. = FALSE)
# vendor table
ds$vendor_data_table <- bind_cols(
tibble(cycle = vendor_dt[[1]][[1]]),
lapply(vendor_dt, `[[`, 2) %>% dplyr::as_tibble())
attr(ds$vendor_data_table, "units") <- NULL # units do not apply
return(ds)
}