View source: R/tensor-baseline-power.R
power_baseline | R Documentation |
Calculate power baseline
power_baseline(
x,
baseline_windows,
method = c("percentage", "sqrt_percentage", "decibel", "zscore", "sqrt_zscore"),
units = c("Trial", "Frequency", "Electrode"),
...
)
## S3 method for class 'rave_prepare_power'
power_baseline(
x,
baseline_windows,
method = c("percentage", "sqrt_percentage", "decibel", "zscore", "sqrt_zscore"),
units = c("Frequency", "Trial", "Electrode"),
electrodes,
...
)
## S3 method for class 'FileArray'
power_baseline(
x,
baseline_windows,
method = c("percentage", "sqrt_percentage", "decibel", "zscore", "sqrt_zscore"),
units = c("Frequency", "Trial", "Electrode"),
filebase = NULL,
...
)
## S3 method for class 'array'
power_baseline(
x,
baseline_windows,
method = c("percentage", "sqrt_percentage", "decibel", "zscore", "sqrt_zscore"),
units = c("Trial", "Frequency", "Electrode"),
...
)
## S3 method for class 'ECoGTensor'
power_baseline(
x,
baseline_windows,
method = c("percentage", "sqrt_percentage", "decibel", "zscore", "sqrt_zscore"),
units = c("Trial", "Frequency", "Electrode"),
filebase = NULL,
hybrid = TRUE,
...
)
x |
R array, |
baseline_windows |
list of baseline window (intervals) |
method |
baseline method; choices are |
units |
the unit of the baseline; see 'Details' |
... |
passed to other methods |
electrodes |
the electrodes to be included in baseline calculation;
for power repository object produced by |
filebase |
where to store the output; default is |
hybrid |
whether the array will be |
The arrays must be four-mode tensor and must have valid named
dimnames
. The dimension names must be 'Trial'
,
'Frequency'
, 'Time'
, 'Electrode'
, case sensitive.
The baseline_windows
determines the baseline windows that are used to
calculate time-points of baseline to be included. This can be one
or more intervals and must pass the validation function
validate_time_window
.
The units
determines the unit of the baseline. It can be one or
more of 'Trial'
, 'Frequency'
, 'Electrode'
. The default
value is all of them, i.e., baseline for each combination of trial,
frequency, and electrode. To share the baseline across trials, please
remove 'Trial'
from units
. To calculate baseline that should
be shared across electrodes (e.g. in some mini-electrodes), remove
'Electrode'
from the units
.
Usually the same type as the input: for arrays,
filearray
,
or ECoGTensor
, the outputs are
also the same type with the same dimensions; for 'rave_prepare_power'
repositories, the results will be stored in its 'baselined'
element;
see 'Examples'.
## Not run:
# The following code need to download additional demo data
# Please see https://rave.wiki/ for more details
library(raveio)
repo <- prepare_subject_power(
subject = "demo/DemoSubject",
time_windows = c(-1, 3),
electrodes = c(14, 15))
##### Direct baseline on the repository
power_baseline(x = repo, method = "decibel",
baseline_windows = list(c(-1, 0), c(2, 3)))
power_mean <- repo$power$baselined$collapse(
keep = c(2,1), method = "mean")
image(power_mean, x = repo$time_points, y = repo$frequency,
xlab = "Time (s)", ylab = "Frequency (Hz)",
main = "Mean power over trial (Baseline: -1~0 & 2~3)")
abline(v = 0, lty = 2, col = 'blue')
text(x = 0, y = 20, "Aud-Onset", col = "blue", cex = 0.6)
##### Alternatively, baseline on electrode instances
baselined <- lapply(repo$power$data_list, function(inst) {
re <- power_baseline(inst, method = "decibel",
baseline_windows = list(c(-1, 0), c(2, 3)))
collapse2(re, keep = c(2,1), method = "mean")
})
power_mean2 <- (baselined[[1]] + baselined[[2]]) / 2
# Same with precision difference
max(abs(power_mean2 - power_mean)) < 1e-6
## End(Not run)