electron_density: Electron Density from Stark Broadening

View source: R/stark.R

electron_densityR Documentation

Electron Density from Stark Broadening

Description

Estimates the electron density of a plasma from the Stark width of an emission line: from the Stark broadening parameters of the line (STARK-B, or a reference width), or from the width of the hydrogen H\alpha line at 656.28 nm.

Usage

electron_density(
  width,
  method = "stark",
  stark = NULL,
  wavelength = NULL,
  temperature = NULL,
  reference_width = NULL,
  reference_density = 1e+17,
  tolerance = 0.5,
  species = NULL
)

Arguments

width

The measured Stark full width at half maximum, in nm (see Details). A vector is allowed.

method

"stark" (default) or "halpha".

stark

For method = "stark": a tibble returned by starkb_lines(). Alternatively, give reference_width.

wavelength

For method = "stark" with stark: the wavelength of the line, in nm.

temperature

For method = "stark" with stark: the plasma temperature, in K.

reference_width

For method = "stark": the electron-impact Stark width (nm) at reference_density, when stark is not given.

reference_density

The density of reference_width, in cm^{-3}. Default is 10^{17}.

tolerance

For method = "stark" with stark: the largest difference between wavelength and the tabulated wavelength, in nm (see stark_width()). Default is 0.5.

species

For method = "stark" with stark: the species of the line, such as "Ca II", required when stark has several species (see stark_width()).

Details

width is the Stark full width at half maximum, in nm, with the instrumental and Doppler broadening removed. The line must be optically thin: self-absorption broadens lines and overestimates the density (see self_absorption()).

  • For isolated lines (method = "stark"), the Stark profile is Lorentzian: use the Lorentzian width wL of a Voigt fit with peak_fit() or multipeak_fit(), whose Gaussian part absorbs the instrumental and Doppler broadening. Holding the Gaussian width at the measured instrumental width combined with the Doppler width (doppler_width()), with fixed = "wG", determines the Lorentzian width much better.

  • The Stark profile of H\alpha (method = "halpha") is not Lorentzian: use the FWHM of the whole line, for example voigt_fwhm() of the fitted widths, corrected for the instrumental width when it is not negligible (for Gaussian broadening, approximately \sqrt{w^2 - w_{inst}^2}).

  • method = "stark": in the impact approximation the Stark width is proportional to the electron density,

    N_e = N_{ref} \frac{w}{w_{ref}(T)}

    where w_{ref}(T) is the electron-impact width at density N_{ref}. It is taken from stark (a table returned by starkb_lines(), interpolated at temperature with stark_width()), or given directly as reference_width (nm) at reference_density. Tables from other sources can be built with stark_table(), or read from saved STARK-B files with read_starkb() and from the VALD3 and Kurucz line lists with read_vald() and read_kurucz(). Ion broadening is neglected, which is usually justified for lines of ions and at LIBS densities.

  • method = "halpha": the computer-simulation fit of Gigosos, González and Cardeñoso (2003) for the H\alpha line,

    w = 1.098\,(N_e / 10^{17})^{0.67823}\ \mathrm{nm},

    which includes the ion dynamics and depends only weakly on temperature.

Value

A numeric vector of electron densities, in cm^{-3}. See electron_density_uncertainty() for their uncertainty.

References

  • Gigosos, M.A., González, M.Á., Cardeñoso, V. (2003). Computer simulated Balmer-alpha, -beta and -gamma Stark line profiles for non-equilibrium plasmas diagnostics. Spectrochimica Acta Part B, 58(8):1489-1504.

  • Konjević, N. (1999). Plasma broadening and shifting of non-hydrogenic spectral lines: present status and applications. Physics Reports, 316(6):339-401.

See Also

starkb_lines(), stark_width(), peak_fit(), voigt_fwhm()

Examples

# From the H-alpha line: a Stark FWHM of 0.5 nm
electron_density(0.5, method = "halpha")

# From a line with known Stark width 0.012 nm at 1e17 cm-3
electron_density(c(0.006, 0.012, 0.024), reference_width = 0.012)

specProc documentation built on Nov. 20, 2026, 5:11 p.m.