tci_plasma: TCI algorithm for plasma targeting

Description Usage Arguments Value

View source: R/tci_algorithms.R

Description

TCI algorithm based on the algorithm described by Jacobs (1990).

Usage

1
tci_plasma(Cpt, pkmod, dtm, maxrt = 1200, cmpt = 1, ...)

Arguments

Cpt

Target plasma concentration

pkmod

PK model

dtm

Duration of the infusion

maxrt

Maximum infusion rate. Defaults to 200 ml/min in reference to the maximum infusion rate of 1200 ml/h permitted by existing TCI pumps (e.g. Anestfusor TCI program).

cmpt

Compartment into which infusions are administered. Defaults to the first compartment.

...

Arguments passed on to pkmod.

Value

Returns a numeric value with length one.