R/water_controls.R

Defines functions controlList positive print.waterControl calcH.control anchors.control

Documented in anchors.control calcH.control

#' Parameters for the selection of anchor pixels
#' @description
#' Parameters of calcAnchors() for METRIC.EB(anchors.control = ).
#' @param deltaTemp  temperature margin (K, default 5): cold candidates must be
#' colder than the 5\% quantile of Ts over well-vegetated pixels plus
#' deltaTemp, and hot candidates warmer than the maximum Ts over bare-soil
#' pixels minus deltaTemp
#' @param minDist    minimum distance (m) between two anchor pixels of the same
#' type
#' @param WSbuffer   maximum distance (m) to the weather station. If no pixel
#' is within WSbuffer, the whole image is used, with a warning
#' @param min.candidates  minimum number of hot and of cold candidates below
#' which a warning is given (the area may be too small or too homogeneous)
#' @param cold.NDVI      anchors.method = "percentile": cold candidates have
#' NDVI at or above this quantile of the NDVI of the area (default 0.95)
#' @param cold.LAI       "percentile": and LAI of at least cold.LAI (default 4)
#' @param cold.fraction  "percentile": the coldest fraction of the cold
#' candidates are the cold anchors (default 0.2)
#' @param hot.NDVI       "percentile": hot candidates have NDVI at or below
#' this quantile (default 0.1), above 0 (no water) and albedo 0.10 to 0.35
#' @param hot.fraction   "percentile": the hottest fraction of the hot
#' candidates are the hot anchors (default 0.2)
#' @param homogeneity    "percentile": maximum standard deviation of Ts (K) in
#' the 5 x 5 pixels around a candidate (default 1.5)
#' @return A list of class waterControl with the parameters.
#' @family METRIC model functions
#' @seealso \code{\link{calcAnchors}}
#' @examples
#' anchors.control(minDist = 1000)
#' @export
anchors.control <- function(deltaTemp = 5, minDist = 500, WSbuffer = 30000,
                            min.candidates = 20, cold.NDVI = 0.95, cold.LAI = 4,
                            cold.fraction = 0.2, hot.NDVI = 0.1, hot.fraction = 0.2,
                            homogeneity = 1.5){
  positive(deltaTemp, "deltaTemp"); positive(minDist, "minDist", zero = TRUE)
  positive(WSbuffer, "WSbuffer"); positive(min.candidates, "min.candidates", zero = TRUE)
  for(p in c("cold.NDVI", "cold.fraction", "hot.NDVI", "hot.fraction")){
    v <- get(p)
    if(!is.numeric(v) || length(v) != 1 || !isTRUE(v > 0 && v <= 1)){
      stop(p, " must be a number above 0 and up to 1", call. = FALSE)
    }
  }
  positive(cold.LAI, "cold.LAI", zero = TRUE); positive(homogeneity, "homogeneity")
  structure(list(deltaTemp = deltaTemp, minDist = minDist, WSbuffer = WSbuffer,
                 min.candidates = min.candidates, cold.NDVI = cold.NDVI,
                 cold.LAI = cold.LAI, cold.fraction = cold.fraction,
                 hot.NDVI = hot.NDVI, hot.fraction = hot.fraction,
                 homogeneity = homogeneity),
            class = c("waterControl", "list"))
}

#' Parameters for the iteration of H and the aerodynamic resistance
#' @description
#' Parameters of calcH() for METRIC.EB(calcH.control = ).
#' @param maxit     maximum number of iterations
#' @param u200.min  minimum wind speed at 200 m (m/s). With a lower wind
#' speed extrapolated from the station, u200.min is used, with a warning. 2
#' m/s corresponds to about 1 m/s at 2 m over grass. A choice of this package,
#' not of Allen et al. (2007)
#' @param damping   weight of the previous aerodynamic resistance in each
#' iteration, 0 (default, no damping) to below 1: r_ah = (1 - damping) * new +
#' damping * previous. Damping keeps the same solution and helps runs that
#' oscillate instead of converging. A choice of this package
#' @param ETrF.hot  reference ET fraction of the hot anchor pixels (default 0,
#' dry bare soil). After rain the soil may still evaporate; Allen et al. (2007,
#' Eq. 47) then compute dT of the hot pixels from Rn - G - LE.hot. METRIC.EB()
#' warns when the station recorded more than 5 mm of rain in the 3 days before
#' the image and ETrF.hot is 0
#' @param cold.NDVI.rule  logical (default FALSE). If TRUE, METRIC.EB() lowers
#' the ET fraction of automatically selected cold anchors with NDVI below 0.8:
#' min(ETp.coef, Kc * ETo / ETr), with Kc = 2.11 NDVI - 0.4989
#' (Reyes-González et al., 2015), for every anchors.method. If FALSE, only
#' "flexible" does it, when the cold criteria had to be relaxed. The NDVI is
#' from top-of-atmosphere reflectance with image.DN, from surface reflectance
#' otherwise
#' @param lapse     lapse rate (K/km) of the surface temperature with
#' elevation, for plain = FALSE (default 6.49): Ts is referred to the
#' elevation of the weather station for the dT calibration and the anchors
#' @param slope.min1  logical (default FALSE). For plain = FALSE, the
#' roughness adjustment for terrain of Allen et al. (2007, Eq. 35), 1 + (slope
#' - 5) / 20, lowers the roughness on slopes below 5 degrees; if TRUE it is at
#' least 1, as in the METRIC manual
#' @return A list of class waterControl with the parameters.
#' @family METRIC model functions
#' @seealso \code{\link{calcH}}
#' @examples
#' calcH.control(maxit = 30)
#' @export
calcH.control <- function(maxit = 20, u200.min = 2, damping = 0, ETrF.hot = 0,
                          cold.NDVI.rule = FALSE, lapse = 6.49, slope.min1 = FALSE){
  if(!is.numeric(maxit) || length(maxit) != 1 || !isTRUE(maxit >= 1) || maxit %% 1 != 0){
    stop("maxit must be a whole number, 1 or more", call. = FALSE)
  }
  positive(u200.min, "u200.min")
  if(!is.numeric(damping) || length(damping) != 1 || !isTRUE(damping >= 0 && damping < 1)){
    stop("damping must be a number from 0 to below 1", call. = FALSE)
  }
  if(!is.numeric(ETrF.hot) || length(ETrF.hot) != 1 || !isTRUE(ETrF.hot >= 0 && ETrF.hot < 1)){
    stop("ETrF.hot must be a number from 0 to below 1", call. = FALSE)
  }
  if(!isTRUE(cold.NDVI.rule) && !isFALSE(cold.NDVI.rule)){
    stop("cold.NDVI.rule must be TRUE or FALSE", call. = FALSE)
  }
  positive(lapse, "lapse", zero = TRUE)
  if(!isTRUE(slope.min1) && !isFALSE(slope.min1)){
    stop("slope.min1 must be TRUE or FALSE", call. = FALSE)
  }
  structure(list(maxit = maxit, u200.min = u200.min, damping = damping,
                 ETrF.hot = ETrF.hot, cold.NDVI.rule = cold.NDVI.rule,
                 lapse = lapse, slope.min1 = slope.min1),
            class = c("waterControl", "list"))
}

#' @export
print.waterControl <- function(x, ...){
  utils::str(unclass(x), give.head = FALSE)
  invisible(x)
}

# a single positive number (or zero)
positive <- function(x, name, zero = FALSE){
  ok <- is.numeric(x) && length(x) == 1 && is.finite(x) && (x > 0 || (zero && x == 0))
  if(!ok){
    stop(name, " must be a number above 0", if(zero) " (or 0)", call. = FALSE)
  }
  invisible(x)
}

# A control list: the defaults of the constructor called name updated with the
# elements of control (a list from it or a plain list); unknown names stop.
# The constructor is taken from the package namespace, as the arguments of
# METRIC.EB() have the same names
controlList <- function(control, name){
  fun <- get(name, envir = environment(controlList), mode = "function")
  if(is.null(control)){return(fun())}
  if(!is.list(control)){stop(name, " must be a list, e.g. from ", name, "()", call. = FALSE)}
  unknown <- setdiff(names(control), names(formals(fun)))
  if(length(unknown) || (length(control) && is.null(names(control)))){
    stop("Unknown elements in ", name, ": ", paste(unknown, collapse = ", "),
         ". Use ", paste(names(formals(fun)), collapse = ", "), call. = FALSE)
  }
  do.call(fun, unclass(control))
}

Try the water package in your browser

Any scripts or data that you put into this service are public.