#' Create graphical parameters for the \code{LG_shiny}-interface.
#'
#' @description This internal function will, based on the values in
#' the \code{TCS_type} part of the \code{input_triggers}, create
#' the next part which is \code{var_local}. This function will
#' also take care of some of the bookkeeping.
#'
#' @param .env The environment where the original arguments given to
#' \code{LG_shiny} lives, i.e. arguments like \code{main_dir} and
#' \code{data_dir}.
#'
#' @param .env2 The environment containing the two lists \code{input}
#' and \code{output}.
#'
#' @return This interface-function creates another graphical
#' parameters part of the \code{LG_shiny}-application.
#'
#' @keywords internal
LG_shiny_TCS_input <- function(
.env,
.env2) {
on.exit(expr = {.env$TS_logging$update$worker$TCS_type <- FALSE})
## In order to avoid unnecessary updates when an actionButton has
## been pushed more than once, it is necessary to have a logical
## value that decides if an update should be performed.
## Moreover, also need to initiate if it is necessary to remove
## some nodes due to insufficient information
.update_required <- FALSE
.remove_these_nodes <- c()
## Create a shortcut to the environment of interest.
..env <- LG_shiny_interface_0_RW_log(.env, .env2, .RW="L")
## Identify old and new values for the triggers.
.old_values <- .env$TS_logging$update$input_triggers$TCS_type
.new_values <- .env$input[names(.old_values)]
## Update the stored values.
.env$TS_logging$update$input_triggers$TCS_type <- .new_values
## In the initiation-phase everything will be '0' in
## '.new_values', and the desired trigger must then be extracted
## from 'TS_logging'. This will be 'NA' the first time around,
## but later on it will be a recording of the value used the last
## time the node was visited.
if (sum(unlist(.new_values)) == 0) {
### REMINDER: Switch the if-test back to the difference
### between new and old when the update of TS_logging is
### performed (i.e. when the stored values are used again).
.trigger <- ..env$.derived_graphical$TCS_type[1]
.env$TS_logging$update$input_triggers$
derived_graphical["TCS_type"] <- .trigger
## Update the information in the 'input'-lists based on the
## present content of the saved data.
LG_shiny_set_values(.env, .env2)
## If '.trigger' is 'NA', then some of the nodes later on
## should be hidden away.
if (is.na(.trigger)) {
## Identify the node-parts to remove.
.tmp <- setdiff(x = names(.env$output_nodes),
y = c("TS_info", "TCS"))
.remove_these_nodes <- unlist(.env$output_nodes[.tmp])
## Use 'eval' + 'bquote' + '.()' construction to update the
## 'output'-list in '.env2', which in this case implies that
## the nodes will be set to 'NULL' in order to hide them.
for (.node in .remove_these_nodes)
eval(expr = bquote(output[[.(.node)]] <- NULL),
envir = .env2)
return(invisible(NULL))
} else
.update_required <- TRUE
} else {
## Detect the position with the difference, i.e. the position
## where the value increased with one. Use the name of that
## position to select a key that describes if the desired
## graph should be related to the time series itself (T),
## based on the local Gaussian correlations (C), or based on
## the local Gaussian spectra (S)
.trigger <- switch(
EXPR = names(.old_values)[as.logical(unlist(.new_values) - unlist(.old_values))],
TS_graphic = "T",
Approx_graphic = "C",
Spectra_graphic = "S")
## Use the trigger to update the information in '..env'
..env$.derived_graphical$TCS_type <- c(
.trigger,
..env$.derived_graphical$TCS_type[1])
## Check if this requires an actual update of the graphical
## interface, i.e. if a new value has been selected.
if (! identical(x = ..env$.derived_graphical$TCS_type[1],
y = ..env$.derived_graphical$TCS_type[2])) {
.update_required <- TRUE
}
}
## Update the information in the input-lists too.
.env$TS_logging$update$input_triggers$derived_graphical["TCS_type"] <-
.trigger
LG_shiny_set_values(.env, .env2,
.part = "derived_graphical")
## Terminate if nothing should be done, otherwise continue.
if (!.update_required) {
return(NULL)
} else
kill(.update_required, .old_values, .new_values)
## Still running? Then a switch has happened, and it is (most
## likely) necessary to update the log-information.
LG_shiny_interface_0_RW_log(.env, .env2, .RW = "W")
## Use '.trigger'-value to call the functions that creates the
## required trigger-specific interfaces.
if (.trigger != "T") {
## Initiate the 'CS'-part of the interface.
LG_shiny_CS_input(.env, .env2, .part = "var_local")
} else {
## Initiate the 'T'-part of the interface.
LG_shiny_T_input(.env, .env2)
}
return(invisible(NULL))
}
Add the following code to your website.