#' chemCheck
#' Function to flag samples if basic chemistry is unreasonable
#' @param qw.data A qw.data list generated from readNWISodbc
#' @param returnAll logical, return dataframe containing all results or only return flagged samples. Defualt is FALSE
#' @details Performs chemical checks for expected ranges of O2, pH, Sc, and chargebalance. Definitions of checks can be found at https://internal.cida.usgs.gov/NAWQA/data_checks/docs/files/check30-sql.html
#' @examples
#' data("exampleData",package="WQReview")
#' chemCheckOut <- chemCheck(qw.data=qw.data,
#' returnAll = FALSE)
#' @importFrom dplyr left_join
#' @export
#' @return A dataframe containing all samples with applicable flags
chemCheck <- function(qw.data, returnAll = FALSE) {
#Make data frame of all samples
inReviewData <- subset(qw.data$PlotTable, DQI_CD %in% c("I","S","P"))
#run ionBalance on inReview data is not present
if(is.null(inReviewData$complete.chem)){
ionbal <- ionBalance(qw.data)
inReviewData <- dplyr::left_join(inReviewData, ionbal[,c("RECORD_NO","PARM_CD","meqCharge","sum_cat","sum_an","complete.chem",
"perc.diff","element")], by = c("RECORD_NO","PARM_CD"))
}
#Check if empty rows and put in a NA row, super hacky but fixes the issue
if(nrow(inReviewData) == 0){
tempDF <- as.data.frame(t(rep(NA,ncol(inReviewData))))
names(tempDF) <- names(inReviewData)
inReviewData <- dplyr::bind_rows(inReviewData,tempDF)
}
inReviewData$SC_badLabVSField <- NA
inReviewData$phTooLow_30.01 <- NA
inReviewData$phTooHigh_30.02 <- NA
inReviewData$O2TooHigh_30.03 <- NA
inReviewData$BadCB_30.21 <- NA
flaggedSamples <- unique(inReviewData[c("RECORD_NO",
"SITE_NO",
"STATION_NM",
"SAMPLE_START_DT",
"SAMPLE_END_DT",
"MEDIUM_CD",
"SAMPLE_CM_TX")])
#Flag samples with bad field vs lab SC
##Subset data to field and lab SC results
fieldSCData <- subset(inReviewData, PARM_CD == "00095" & MEDIUM_CD != "OAQ")
labSCData <- subset(inReviewData, PARM_CD == "90095" & MEDIUM_CD != "OAQ")
SCData <- dplyr::left_join(fieldSCData[c("RECORD_NO","RESULT_VA")], labSCData[c("RECORD_NO","RESULT_VA","SC_badLabVSField")], by="RECORD_NO")
rm(fieldSCData)
rm(labSCData)
colnames(SCData) <- c("RECORD_NO","fieldSC","labSC","SC_badLabVSField")
#SCData <- na.omit(SCData)
SCData$perc.diff <- (SCData$labSC - SCData$fieldSC)/SCData$fieldSC * 100
###Flag samples
SCData$SC_badLabVSField[which(abs(SCData$perc.diff) > 10)] <- paste("flag",
"field=",SCData$fieldSC[which(abs(SCData$perc.diff) > 10)],
"lab=",SCData$labSC[which(abs(SCData$perc.diff) > 10)],
"percDiff=",SCData$perc.diff[which(abs(SCData$perc.diff) > 10)])
##Subset data to pH results
pHData <- subset(inReviewData, PARM_CD == "00400")
##Flag samples that are too low
###Make empty vector for flags
###Flag samples
pHData$phTooLow_30.01[which(pHData$RESULT_VA < 4.5)] <- paste("flag",
pHData$RESULT_VA[which(pHData$RESULT_VA < 4.5)])
##Flag samples that are too high
###Make empty vector for flags
###Flag samples
pHData$phTooHigh_30.02[which(pHData$RESULT_VA > 9)] <- paste("flag",
pHData$RESULT_VA[which(pHData$RESULT_VA > 9)])
#Flag samples with high O2
##Subset data to O2 results
O2Data <- subset(inReviewData, PARM_CD == "00300")
##Flag samples that are too high
###Make empty vector for flags
###Flag samples
O2Data$O2TooHigh_30.03[which(O2Data$RESULT_VA > 25)] <- paste("flag",
O2Data$RESULT_VA[which(O2Data$RESULT_VA > 25)])
#Flag samples with bad charge balance
#Check if charge balance was run and throw a warning if not
if(is.null(inReviewData$complete.chem))
{
warning("No charge balance data. Try running ionBalance() on qw.data list input first.")
cbData <- subset(inReviewData, PARM_CD == "00095" & MEDIUM_CD != "OAQ")
cbData$BadCB_30.21 <- NA
} else {
##Subset to samples with SC data
cbData <- subset(inReviewData, PARM_CD == "00095" & MEDIUM_CD != "OAQ" & complete.chem == "Complete")
##Make empty vector for flags
###Flag samples
cbData$BadCB_30.21[which(cbData$RESULT_VA <= 100 &
abs(cbData$perc.diff) > 15)] <- paste("flag",
"SC=",
cbData$RESULT_VA[which(cbData$RESULT_VA <= 100 &
abs(cbData$perc.diff) > 15)],
"perc diff=",
cbData$perc.diff[which(cbData$RESULT_VA <= 100 &
abs(cbData$perc.diff) > 15)]
)
cbData$BadCB_30.21[which(cbData$RESULT_VA > 100 &
cbData$RESULT_VA <= 1000 &
abs(cbData$perc.diff) > 10)] <- paste("flag",
"SC=",
cbData$RESULT_VA[which(cbData$RESULT_VA > 100 &
cbData$RESULT_VA <= 1000 &
abs(cbData$perc.diff) > 10)],
"perc diff=",
cbData$perc.diff[which(cbData$RESULT_VA > 100 &
cbData$RESULT_VA <= 1000 &
abs(cbData$perc.diff) > 10)]
)
cbData$BadCB_30.21[which(cbData$RESULT_VA > 1000 &
abs(cbData$perc.diff) > 5)] <- paste("flag",
"SC=",
cbData$RESULT_VA[which(cbData$RESULT_VA > 1000 &
abs(cbData$perc.diff) > 5)],
"perc diff=",
cbData$perc.diff[which(cbData$RESULT_VA > 1000 &
abs(cbData$perc.diff) > 5)]
)
}
#Join flagged samples together into one dataframe
flaggedSamples <- dplyr::left_join(flaggedSamples,
SCData[c("RECORD_NO","SC_badLabVSField")],
by = "RECORD_NO")
flaggedSamples <- dplyr::left_join(flaggedSamples,
pHData[c("RECORD_NO","phTooLow_30.01")],
by = "RECORD_NO")
flaggedSamples <- dplyr::left_join(flaggedSamples,
pHData[c("RECORD_NO","phTooHigh_30.02")],
by = "RECORD_NO")
flaggedSamples <- dplyr::left_join(flaggedSamples,
O2Data[c("RECORD_NO","O2TooHigh_30.03")],
by = "RECORD_NO")
flaggedSamples <- dplyr::left_join(flaggedSamples,
cbData[c("RECORD_NO","BadCB_30.21")],
by = "RECORD_NO")
flaggedSamples <- unique(flaggedSamples)
if(returnAll == FALSE)
{
#remove NAs from result flags
flaggedSamples <- unique(flaggedSamples[which(!is.na(flaggedSamples[8]) |
!is.na(flaggedSamples[9]) |
!is.na(flaggedSamples[10]) |
!is.na(flaggedSamples[11]) |
!is.na(flaggedSamples[12])
),])
} else {}
return(unique(flaggedSamples))
}