cooling_detail: cooling_detail

cooling_detailR Documentation

cooling_detail

Description

Detailed cooling information.

Utility ID

EIA-assigned identification number for the company that is responsible for the day-to-day operations of the generator

State

State of operator

Plant Code

Code of plant

Plant Name

Name of plant

Year

Year

Month
Generator ID

Generator identification number

Boiler ID

Boiler identification number

Cooling ID

Cooling system identification number

Generator Primary Technology

High level description of the technology used by the generator to produce electricity

Summer Capacity of Steam Turbines (MW)
Gross Generation from Steam Turbines (MWh)
Net Generation from Steam Turbines (MWh)
Summer Capacity Associated with Single Shaft Combined Cycle Units (MW)
Gross Generation Associated with Single Shaft Combined Cycle Units (MWh)
Net Generation Associated with Single Shaft Combined Cycle Units (MWh)
Fuel Consumption from All Fuel Types (MMBTU)
Coal Consumption (MMBTU)

Coal consumed

Natural Gas Consumption (MMBTU)

Natural gas consumed

Petroleum Consumption (MMBTU)

Petroleum consumed

Biomass Consumption (MMBTU)

Biomass consumption

Other Gas Consumption (MMBTU)

Other gas consumption

Other Fuel Consumption (MMBTU)

Fuel consumption

Water Withdrawal Volume (Million Gallons)

Volume of water withdrawals

Water Consumption Volume (Million Gallons)

Volume of water consumed

Water Withdrawal Intensity Rate (Gallons / MWh)
Water Withdrawal Rate per Fuel Consumption (Gallons / MMBTU)
Cooling Unit Hours in Service
Average Distance of Water Intake Below Water Surface (Feet)
860 Cooling Type 1

Type of cooling system

860 Cooling Type 2

Type of cooling system

923 Cooling Type
Cooling System Type
Water Type
Code Description
BR Brackish Water
FR Fresh Water
BE Reclaimed Water (ex: treated wastewater effluent)
SA Saline Water
OT Other (specify in SCHEDULE 7)
Water Source
Code Description
SW Surface Water (ex: river, canal, bay)
GW Ground Water (ex: aquifer, well)
PD Plant Discharge Water (ex: wastewater treatment plant discharge)
OT Other (specify in SCHEDULE 7)
Water Source Name

Name of river, lake, or water source that provides cooling water

Water Discharge Name

Name of river, lake, or water source that cooling water is discharged into.

Generator Status
Generator Inservice Month
Generator Inservice Year
Generator Retirement Month
Generator Retirement Year
Boiler Status
Code Description
CN Cancelled (previously reported as “planned”)
CO New unit under construction
OP Operating (in commercial service or out of service less than 365 days)
OS Out of service (365 days or longer)
PL Planned (expected to go into commercial service within 10 years)
RE Retired (no longer in service and not expected to be returned to service)
SB Standby (or inactive reserve); i.e., not normally used, but available for service
SC Cold Standby (Reserve); deactivated (usually requires 3 to 6 months to reactivate)
TS Operating under test conditions (not in commercial service)
Boiler Inservice Month
Boiler Inservice Year
Boiler Retirement Month
Boiler Retirement Year
Cooling Status
Code Description
CN Cancelled (previously reported as “planned”)
CO New unit under construction
OP Operating (in commercial service or out of service less than 365 days)
OS Out of service (365 days or longer)
PL Planned (expected to go into commercial service within 10 years)
RE Retired (no longer in service and not expected to be returned to service)
SB Standby (or inactive reserve); i.e., not normally used, but available for service
SC Cold Standby (Reserve); deactivated (usually requires 3 to 6 months to reactivate)
TS Operating under test conditions (not in commercial service)
Cooling Inservice Month

The actual or projected in-service month of this cooling system

Cooling Inservice Year

The actual or projected in-service month of this cooling system

Combined Heat and Power Generator?

Indicates whether the generator is associated with a combined heat and power system (Yes/No)

Usage

cooling_detail

Format

A dataframe with 584820 rows and 70 columns.


capellett/EIAdatasets documentation built on Nov. 3, 2024, 2:04 p.m.