pk_2cmt_bolus_cmax_ss: Cmax for 2-compartmental PK model, bolus dosing at steady...

Description Usage Arguments Examples

Description

Cmax for 2-compartmental PK model, bolus dosing at steady state

Usage

1
2
pk_2cmt_bolus_cmax_ss(dose = 100, tau = 12, CL = 3, V = 30, Q = 2,
  V2 = 20, ruv = NULL)

Arguments

dose

dose

tau

dosing interval

CL

clearance

V

volume of central compartment

Q

inter-compartimental clearance

V2

volume of peripheral compartment

ruv

residual error (list)

Examples

1
pk_2cmt_bolus_cmax_ss(dose = 1000, tau = 12, CL = 5, V = 50, Q = 20, V2 = 200)

ronkeizer/clinPK documentation built on May 20, 2019, 5:07 p.m.