Description

Concentration predictions for 1-compartmental PK model after single or multiple bolus doses

Usage

1
2
pk_1cmt_bolus(t = c(0:24), dose = 100, tau = 12, CL = 3, V = 30,
  ruv = NULL)

Arguments

t

vector of time

dose

dose

tau

dosing interval

CL

clearance

V

volume of distribution

ruv

residual error (list)

Examples

1
2
3
4
5
pk_1cmt_bolus(dose = 500, tau = 12, CL = 5, V = 50)
pk_1cmt_bolus(dose = 500, tau = 12, CL = 5, V = 50, t = 24)
pk_1cmt_bolus(
  dose = 500, tau = 12, CL = 5, V = 50,
  ruv = list(prop = 0.1, add = 0.1))