clint_L3 | R Documentation |
Mass Spectrometry measurements of intrinsic hepatic clearance (Clint) for cryopreserved pooled human hepatocytes. Chemicals were per- and poly-fluorinated alkyl substance (PFAS) samples. The experiments were led by Dr.s Marci Smeltz and Barbara Wetmore \insertCitesmeltz2023plasmainvitroTKstats. This data set is a subset of experimental data containing samples for 3 test analytes/compounds.
clint_L3
A level-3 data.frame with 3 rows and 13 variables:
Compound.Name
Name of the test analyte/compound
DTXSID
DSSTox Substance Identifier (CompTox Chemicals Dashboard - CCD)
Lab.Compound.Name
Compound as described in the laboratory
Calibration
Identifier for mass spectrometry calibration – usually the date
Clint
Intrinsic hepatic clearance
Clint.pValue
p-value of estimated Clint
value
Fit
Test nominal concentrations
AIC
Akaike Information Criterion of the linear regression fit
AIC.Null
Akaike Information Criterion of the exponential decay assuming a constant rate of decay
Clint.1
Intrinsic hepatic clearance at 1 uM
Clint.10
Intrinsinc hepatic clearance at 10 uM
AIC.Sat
Akaike Information Criterion of the exponential decay with a saturation probability
Sat.pValue
p-value of exponential decay with a saturation probability
shibata2002predictioninvitroTKstats
\insertRefsmeltz2023plasmainvitroTKstats
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.