| voigt_fwhm | R Documentation |
Computes the full width at half maximum (FWHM) of a Voigt profile from its Gaussian and Lorentzian widths, with the approximation of Olivero and Longbothum (1977), accurate to about 0.02%:
f_V \approx 0.5346\,f_L + \sqrt{0.2166\,f_L^2 + f_G^2}
voigt_fwhm(wG, wL)
wG, wL |
The Gaussian and Lorentzian full widths at half maximum, for
example the |
The total width of a fitted line is often better determined than its
split into Gaussian and Lorentzian parts, which trade off against each
other when a line is noisy or sampled by few channels. It is the width to
use for the H\alpha line in electron_density(), whose Stark
profile is not Lorentzian.
A numeric vector of Voigt FWHM, in the units of wG and wL.
Christian L. Goueguel
Olivero, J.J., Longbothum, R.L. (1977). Empirical fits to the Voigt line width: a brief review. Journal of Quantitative Spectroscopy and Radiative Transfer, 17(2):233-236.
voigt_profile(), peak_fit(), electron_density()
voigt_fwhm(wG = 0.1, wL = 0) # Gaussian limit
voigt_fwhm(wG = 0, wL = 0.1) # Lorentzian limit
voigt_fwhm(wG = 0.1, wL = 0.1)