calcATHBpmv2015 | R Documentation |
calcATHBpmv2015
calculates the PMV based on adaptive thermal heat balance framework
based on the original method published 2015
calcATHBpmv2015(trm, psych, ta, tr, vel, rh, met, wme = 0)
trm |
- Running mean outdoor temperature in [degree C] |
psych |
- factor related to fixed effect on perceived control |
ta |
- a numeric value presenting air temperature in [degree C] |
tr |
- a numeric value presenting mean radiant temperature in [degree C] |
vel |
- a numeric value presenting air velocity in [m/s] |
rh |
- a numeric value presenting relative humidity [%] |
met |
- a numeric value presenting metabolic rate in [met] |
wme |
- a numeric value presenting external work in [met] |
aliases athb2015 ATHB2015 athbOld ATHBOLD
All variables must have the same length 1. For the calculation of several values use function calcComfInd
.
calcATHBpmv2015
PMV value adapted through the ATHB appoach
Marcel Schweiker
Schweiker & Wagner (2015) <doi:10.1016/j.buildenv.2015.08.018> Schweiker & Wagner (2016) Exploring potentials and limitations of the adaptive thermal heat balance framework Proceedings of 9th Windsor Conference: making comfort relevant Cumberland Lodge, Windsor, UK, 2016
see also calcComfInd
, link{calcATHBpts}
, link{calcATHBset}
calcATHBpmv2015(20, 0, 25, 25, .1, 50, 1.1)
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.