calcMRTglobe | R Documentation |
calcMRTglobe
calculates the mean radiant temperature considering mixed convection
calcMRTglobe(tg, ta, vel, x = 0.15)
tg |
- a numeric value presenting globe temperature in [degree C] |
ta |
- a numeric value presenting air temperature in [degree C] |
vel |
- a numeric value presenting air velocity in [m/s] |
x |
- a numeric value presenting globe diameter in [m] |
aliases MRT globe
This model has only been validated from x = 0.040m (ping pong ball) to
x = 0.150m (standard globe thermometer) globes
calcMRTglobe
MRT with standard and mixed correction
code implemented into R by Shaomi Rahman and Marcel Schweiker.
Teitelbaum et al. (2022) <10.1038/s41598-022-10172-5> Teitelbaum (2022) <https://github.com/eteitelb/MixedConvection>
#Globe temperature [C]
tg <- 30
#Air temperature [C]
ta <- 24
#Air speed [m/s]
vel <- 0.0
calcMRTglobe(tg, ta, vel)
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.