calcPS | R Documentation |
calcPS
calculates Predicted Percentage Satisfied with the Level of Air
Movement based on the 2-Node-Model by Gagge et al.
calcPS(ta, tr, vel, rh, clo = 0.5, met = 1, wme = 0, pb = 760, ltime = 60,
ht = 171, wt = 70, tu = 40, obj = "set", csw = 170, cdil = 120, cstr = 0.5)
ta |
a numeric value presenting air temperature in [degree C] |
tr |
a numeric value presenting mean radiant temperature in [degree C] |
vel |
a numeric value presenting air velocity in [m/s] |
rh |
a numeric value presenting relative humidity [%] |
clo |
a numeric value presenting clothing insulation level in [clo] |
met |
a numeric value presenting metabolic rate in [met] |
wme |
a numeric value presenting external work in [met] |
pb |
a numeric value presenting barometric pressure in [torr] or [mmHg] |
ltime |
a numeric value presenting exposure time in [minutes] |
ht |
a numeric value presenting body height in [cm] |
wt |
a numeric value presenting body weight in [kg] |
tu |
a numeric value presenting turbulence intensity in [%] |
obj |
a character element, either "set" or "pmvadj" |
csw |
a numeric value presenting the driving coefficient for regulatory sweating |
cdil |
a numeric value presenting the driving coefficient for vasodilation |
cstr |
a numeric value presenting the driving coefficient for vasoconstriction |
All variables must have the same length 1. For the calculation of several
values use function calcComfInd
. The value of obj
defines
whether the function will use the version presented in ASHRAE 55-2013 for
adjustment of pmv (obj = "pmvadj"), or the original code by Gagge to calculate
set (obj = "set"). In the version presented in ASHRAE 55-2013, the lines of
code related to self-generated convection is deleted. Therefore, a difference
can only be seen at higher values of met.
calcPS
returns the Predicted Percentage Satisfied with the Level of
Air Movement
In case one of the variables is not given, a standard value will be taken
from a list (see createCond
for details).
The code for calc2Node
is based on the code in BASIC and C++ presented
by Fountain and Huizenga (1995). The translation into R-language and comparison
with ASHRAE 55-2013 conducted by Marcel Schweiker.
ASHRAE Standard 55-2013. Thermal environmental conditions for human occupancy. American society of heating, Refrigerating and Air-Conditioning Engineering, Atlanta, USA, 2013.
Fountain & Huizenga (1995) A thermal sensation model for use by the engineering profession ASHRAE RP-781 Final report.
Gagge, Fobelets & Berglund (1986) A standard predictive index of human response to the thermal environment, ASHRAE transactions, 92 (2B), 709-731.
see also calcComfInd
## Using several rows of data:
ta <- c(20,22,24)
tr <- ta
vel <- rep(.15,3)
rh <- rep(50,3)
maxLength <- max(sapply(list(ta, tr, vel, rh), length))
ps <- sapply(seq(maxLength), function(x) { calcPS(ta[x], tr[x], vel[x], rh[x]) } )