calcATHBx: PMV based on Adaptive Thermal Heat Balance Framework for the...

View source: R/calcATHBx.R

calcATHBxR Documentation

PMV based on Adaptive Thermal Heat Balance Framework for the extended Model

Description

calcATHBx calculates the PMV based on adaptive thermal heat balance framework

based on the newest version (2022)

Usage

calcATHBx(trm, ta, tr, vel, rh, met, buildingTypeSimple, 
coolingStrategyBuilding, seasonSimple)

Arguments

trm

- Running mean outdoor temperature in [degree C]

ta

- a numeric value presenting air temperature in [degree C]

tr

- a numeric value presenting mean radiant temperature in [degree C]

vel

- a numeric value presenting air velocity in [m/s]

rh

- a numeric value presenting relative humidity [%]

met

- a numeric value presenting metabolic rate in [met]

buildingTypeSimple

- simple building type. Value can be among Multifamily housing, Office as a string

coolingStrategyBuilding

- the process in which the building was ventilated. Value can be among Mixed Mode','Naturally Ventilated' as a String

seasonSimple

- season. Value can be among 'Spring','Summer', 'Winter' as a String

Details

aliases athb ATHB

Value

calcATHBx PMV value adapted through the ATHB approach with extended model

Author(s)

Code implemented in to R by Shaomi Rahman. Further contribution by Marcel Schweiker.

References

Schweiker & Wagner (2015) <doi:10.1016/j.buildenv.2015.08.018> Schweiker (2022) <doi:10.1111/ina.13018>

See Also

see also calcComfInd, link{calcATHBpts}, link{calcATHBset},

link{calcATHBpmv2015}

Examples

calcATHBx(20, 25, 25, .1, 50, 1.1, 'Office', 'Mixed Mode', 
'winter')

marcelschweiker/comfort_R documentation built on Feb. 22, 2024, 9:04 p.m.