| calcATHBx | R Documentation | 
calcATHBx calculates the PMV based on adaptive thermal heat balance framework
based on the newest version (2022)
calcATHBx(trm, ta, tr, vel, rh, met, buildingTypeSimple, 
coolingStrategyBuilding, seasonSimple)
trm | 
 - Running mean outdoor temperature in [degree C]  | 
ta | 
 - a numeric value presenting air temperature in [degree C]  | 
tr | 
 - a numeric value presenting mean radiant temperature in [degree C]  | 
vel | 
 - a numeric value presenting air velocity in [m/s]  | 
rh | 
 - a numeric value presenting relative humidity [%]  | 
met | 
 - a numeric value presenting metabolic rate in [met]  | 
buildingTypeSimple | 
 - simple building type. Value can be among Multifamily housing, Office as a string  | 
coolingStrategyBuilding | 
 - the process in which the building was ventilated. Value can be among Mixed Mode','Naturally Ventilated' as a String  | 
seasonSimple | 
 - season. Value can be among 'Spring','Summer', 'Winter' as a String  | 
aliases athb ATHB
calcATHBx PMV value adapted through the ATHB approach with extended model
Code implemented in to R by Shaomi Rahman. Further contribution by Marcel Schweiker.
Schweiker & Wagner (2015) <doi:10.1016/j.buildenv.2015.08.018> Schweiker (2022) <doi:10.1111/ina.13018>
see also calcComfInd, link{calcATHBpts}, link{calcATHBset},
link{calcATHBpmv2015}
calcATHBx(20, 25, 25, .1, 50, 1.1, 'Office', 'Mixed Mode', 
'winter')
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.