Description

Concentration predictions for 1-compartmental PK model with infusion dosing at steady state

Usage

1
2
pk_2cmt_inf_ss(t = c(0:24), dose = 100, t_inf = 1, tau = 12, CL = 3,
  V = 30, Q = 2, V2 = 20, ruv = NULL)

Arguments

t

vector of time

dose

dose

t_inf

infusion time

tau

dosing interval

CL

clearance

V

volume of distribution

Q

inter-compartimental clearance

V2

volume of peripheral compartment

ruv

residual variability, specified as list with optional arguments for proportional, additive, or exponential components, e.g. 'list(prop=0.1, add=1, exp=0)'

Examples

1
2
3
pk_2cmt_inf_ss(
  dose = 1000, tau = 12, t_inf = 2,
  CL = 5, V = 50, Q = 20, V2 = 200)