View source: R/load_sipes2017.R
load_sipes2017 | R Documentation |
This function returns an updated version of
chem.physical_and_invitro.data
that includes quantitative
structure-property relationship (QSPR) predictions from Simulations Plus'
ADMET predictor as
used in Sipes et al. 2017, included in sipes2017
.
load_sipes2017(overwrite = FALSE, chem_include = NULL, target.env = .GlobalEnv)
overwrite |
Only matters if load.image=FALSE. If overwrite=TRUE then existing data in chem.physical_and_invitro.data will be replaced by any predictions in Sipes et al. (2017) that is for the same chemical and property. If overwrite=FALSE (DEFAULT) then new data for the same chemical and property are ignored. Funbound.plasma values of 0 (below limit of detection) are overwritten either way. |
chem_include |
A vector of CAS numbers indicating only the chemicals to be included in the loading process. If set to 'NULL' all applicable chemicals are loaded. (Default is 'NULL'.) |
target.env |
The environment where the new
|
Because Clint and Fup are the only measurements required for many HTTK models,
changing the number of chemicals for which a value is available will change
the number of chemicals which are listed with the get_cheminfo
command. Use the command reset_httk
to return to the initial
(measured only) chem.physical_and_invitro.data
(for all
parameters).
data.frame |
An updated version of
|
Robert Pearce and John Wambaugh
Sipes, Nisha S., et al. "An intuitive approach for predicting potential human health risk with the Tox21 10k library." Environmental Science & Technology 51.18 (2017): 10786-10796.
reset_httk
get_cheminfo
# Count how many chemicals for which HTTK is available without the QSPR:
num.chems <- length(get_cheminfo())
print(num.chems)
# For chemicals with Sipes et al. (2017) Clint and Fup QSPR predictions,
# add them to our chemical information wherever measured values are
# unavailable:
load_sipes2017()
# Here's a chemical we didn't have before (this one is a good test since the
# logP is nearly 10 and it probably wouldn't work in vitro):
calc_css(chem.cas="26040-51-7")
# Let's see how many chemicals we have now with the Sipes et al. (2017)
# predictions data loaded:
length(get_cheminfo())
# Now let us reset the chemical data to the initial version:
reset_httk()
# We should be back to our original number:
num.chems == length(get_cheminfo())
# Demonstrate loading data for specific chemicals:
#
# Find chemicals with a clint and no fup:
subset(chem.physical_and_invitro.data,!is.na(Human.Clint) & Human.Funbound.plasma==0)$CAS
chem1 <- "101-05-3"
chem2 <- "2971-36-0"
# Take a look at what parameterize_steadystate gives (working from a default fup of 0.005):
a1 <- parameterize_steadystate(chem.cas=chem1)
a2 <- parameterize_steadystate(chem.cas=chem2)
# load Sipes for this chemical:
load_sipes2017(chem_include=chem1)
# Check values, only fup for the first chemical should change:
a3 <- parameterize_steadystate(chem.cas=chem1)
a4 <- parameterize_steadystate(chem.cas=chem2)
# All tests should be true:
a1[["Clint"]] == a3[["Clint"]]
a1[["Funbound.plasma"]] != a3[["Funbound.plasma"]]
a2[["Clint"]] == a4[["Clint"]]
a2[["Funbound.plasma"]] == a4[["Funbound.plasma"]]
# load Sipes for this chemical, but allow it to overwrite the clint:
load_sipes2017(chem_include=chem1, overwrite=TRUE)
# Check values, both clint and fup for the first chemical should change:
a5 <- parameterize_steadystate(chem.cas=chem1)
a6 <- parameterize_steadystate(chem.cas=chem2)
# All tests should be true:
a1[["Clint"]] != a5[["Clint"]]
a1[["Funbound.plasma"]] != a5[["Funbound.plasma"]]
a2[["Clint"]] == a6[["Clint"]]
a2[["Funbound.plasma"]] == a6[["Funbound.plasma"]]
# Load Sipes for all chemicals, fup should change for second chemical:
load_sipes2017()
a7 <- parameterize_steadystate(chem.cas=chem1)
a8 <- parameterize_steadystate(chem.cas=chem2)
# All tests should be true:
a1[["Clint"]] != a7[["Clint"]]
a1[["Funbound.plasma"]] != a7[["Funbound.plasma"]]
a2[["Clint"]] == a8[["Clint"]]
a2[["Funbound.plasma"]] != a8[["Funbound.plasma"]]
# load Sipes for this chemical, but allow it to overwrite all clints:
load_sipes2017(overwrite=TRUE)
# Both clint and fup should now be changed for second chemical:
a9 <- parameterize_steadystate(chem.cas=chem1)
a10 <- parameterize_steadystate(chem.cas=chem2)
# All tests should be true:
a1[["Clint"]] != a9[["Clint"]]
a1[["Funbound.plasma"]] != a9[["Funbound.plasma"]]
a2[["Clint"]] != a10[["Clint"]]
a2[["Funbound.plasma"]] != a10[["Funbound.plasma"]]
Add the following code to your website.