system_set_bolus: Set Bolus Inputs

Description Usage Arguments Value See Also Examples

View source: R/ubiquity.r

Description

Defines infusion rates specified in the system file using <B:times> and <B:events>

Usage

1
system_set_bolus(cfg, state, times, values)

Arguments

cfg

ubiquity system object

state

name of the state to apply the bolus

times

list of injection times

values

corresponding list injection values

Value

Ubiquity system object with the bolus information set

See Also

system_zero_inputs

Examples

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
# Creating a system file from the mab_pk example
fr = system_new(file_name        = "system.txt", 
                system_file      = "mab_pk", 
                overwrite        = TRUE, 
                output_directory = tempdir())

# Building the system 
cfg = build_system(system_file  = file.path(tempdir(), "system.txt"),
      output_directory          = file.path(tempdir(), "output"),
      temporary_directory       = tempdir())

# Clearing all inputs
cfg = system_zero_inputs(cfg)

# SC dose of 200 mg
cfg = system_set_bolus(cfg, state   ="At", 
                            times   = c(  0.0),  #  day
                            values  = c(200.0))  #  mg