View source: R/diagnostic_parameters.R
get_lab_parameters | R Documentation |
Sets the baseline lab parameters.
get_lab_parameters(overrides = list())
overrides |
Named list of parameter values to use instead of defaults The parameters are defined below, and are taken from the default settings in the ESFT. |
Requirements per Lab:
lab_staff_per_lab - multiplier that helps estimate lab staff equipment requirements; default = 3
hygienists_per_lab - multiplier that helps estimate lab hygienist/cleaner equipment requirements; default = 3
safety_boxes_per_unit_week - WHO recommendation for safe sharp disposal; default = 8
triple_packaging_per_unit - WHO recommendation for sample transport; default = 4
perc_wastage_manual_test_kits - percentage wastage, only of manual test kits; default = 10 %
num_tests_manual_test_kits - number of tests in an RT-PCR manual test kit; default = 100