Nothing
# Load function input:
data("panobinostat_2DTPP_smallExample")
cfg <- panobinostat_2DTPP_config
dat <- panobinostat_2DTPP_data
dataPath <- system.file("example_data", package="TPP") %>%
file.path(., "2D_example_data")
# Start tests:
test_that(desc="allOK", code={
cfgIn <- cfg
datIn <- dat
out <- analyze2DTPP(configTable = cfgIn,
data = datIn,
idVar = "representative",
addCol = c("clustername", "msexperiment_id"),
intensityStr = "sumionarea_protein_",
qualColName = c("qupm", "qusm"),
nonZeroCols = "qusm",
fcStr = NULL)
expect_equal(nrow(out), 4656)
})
test_that(desc="allOK_scientific_drug_concentration_format", code={
## Motivated by a bug report from Isabelle (2016-12-07)
cfgIn <- cfg
cfgIn[c(1,3,5,7,9,11), "128L"] <- "2E-2"
cfgIn[c(1,3,5,7,9,11)+1, "130H"] <- "2E-2"
datIn <- dat
out <- analyze2DTPP(configTable = cfgIn,
data = datIn,
idVar = "representative",
addCol = c("clustername", "msexperiment_id"),
intensityStr = "sumionarea_protein_",
qualColName = c("qupm", "qusm"),
nonZeroCols = "qusm",
fcStr = NULL)
expect_equal(nrow(out), 4656)
expect_equal(grep("0.02", colnames(out), value = TRUE),
c("norm_rel_fc_protein_0.02_unmodified",
"norm_rel_fc_protein_0.02_normalized_to_lowest_conc",
"norm_rel_fc_protein_0.02_transformed",
"sumionarea_protein_0.02",
"rel_fc_protein_0.02")) # The '-' character will be converted to '.' by the data.frame command when producing the wide result table.
})
test_that(desc="warning_deprecated_fct_arg", code={
cfgIn <- cfg
datIn <- dat
expect_warning(
analyze2DTPP(configFile = cfgIn,
data = datIn,
idVar = "representative",
addCol = c("clustername", "msexperiment_id"),
intensityStr = "sumionarea_protein_",
qualColName = c("qupm", "qusm"),
nonZeroCols = "qusm",
fcStr = NULL)
)
})
# test_that(desc="allOK_obtain_paths_from_config", code={
#
# cfgIn <- openxlsx::read.xlsx(file.path(dataPath, "Panobinostat_TPP-2D_config.xlsx")) %>% select(-Path)
#
# files <- tibble(Experiment = c("X020466", "X020467", "X020468", "X020469", "X020470", "X020471"),
# Path = c("PFC_39106_PF1_QV1_P0101868C.txt",
# "PFC_39108_PF1_QV1_P0101878C.txt",
# "PFC_39110_PF1_QV1_P0101888C.txt",
# "PFC_39101_PF1_QV1_P0101898C.txt",
# "PFC_39099_PF1_QV1_P0101908C.txt",
# "PFC_39093_PF1_QV1_P0101918C.txt") %>% file.path(dataPath, .))
#
# cfgIn <- cfgIn %>% left_join(files)
#
# out <- analyze2DTPP(configTable = cfgIn,
# idVar = "representative",
# addCol = c("clustername", "msexperiment_id"),
# intensityStr = "sumionarea_protein_",
# qualColName = c("qupm", "qusm"),
# nonZeroCols = "qusm",
# fcStr = NULL)
#
# check1 <- any(grepl("TPP_results", dir(dataPath))) # Was result path correctly created from the config file?
# check2 <- all.equal(dim(out), c(61938, 46))
# check3 <- all.equal(out$pEC50 %>% range(na.rm = TRUE), c(5.728183, 8.126123))
# check4 <- all.equal(out$compound_effect %>% table %>% as.numeric, c(1921, 1092))
# check5 <- all.equal(out$pEC50_outside_conc_range %>% table() %>% as.numeric(), c(1450, 1562))
# expect_true(check1 & check2 & check3 & check4 & check5)
# })
## to do:
# test_that(desc="different_concentrations_per_experiment", code={
# cfgIn <- cfg
# cfgIn[1, "128L"] <- 0.01
#
# ## current to do: produce an informative error message stating that we currently can only handle the same concentrations across all temperatures.
# ## long-term: enable different concentrations for different temperatures.
# })
Any scripts or data that you put into this service are public.